Where is output measured?
The source raises the top node above ground. Upper resistor R1 connects that node to the output, and lower resistor R2 connects the output to ground. The output voltage is measured from the output node to that same ground. In Loaded mode, RL connects the output to ground in parallel with R2. Unloaded means that external branch is absent; it does not mean a zero-ohm load.
How does a load change the divider?
Without a load, the output is Vin × R2 / (R1 + R2). With a resistor load, first combine the lower branches: Rb = R2 × RL / (R2 + RL). The source sees Rt = R1 + Rb, and Vout = Vin × Rb / Rt. A finite positive load lowers the divider gain because its parallel resistance is smaller than R2 alone.
For an original worked example, use a 12 V source and three 1 kΩ resistors, with the third serving as RL. Rb is 500 Ω, Rt is 1,500 Ω and the output is 4 V. Removing RL gives 6 V. The voltage difference is 2 V, and the divider ratio falls by 33⅓%. This compares gains defined from the resistances, so the percentage remains defined even when Vin is zero.
What currents and powers are calculated?
The source current I1 = Vin / Rt flows through R1 and then splits: I2 = Vout / R2 and IL = Vout / RL. With no load, IL is exactly zero. The loaded example above has 8 mA through R1, 4 mA through R2 and 4 mA through RL. Using 8 mA for every branch would overstate the lower-resistor powers.
R1 dissipates (Vin − Vout) × I1; R2 dissipates Vout × I2; RL dissipates Vout × IL. The ideal source delivers Vin × I1. In the example these are 64 mW, 16 mW, 16 mW and 96 mW respectively. The model checks exact current balance, voltage balance and total power balance before returning a result. Displayed approximations can differ in their final digit when added.
What is the unloaded Thevenin equivalent?
The open-circuit Thevenin voltage is the unloaded output. With the ideal voltage source set to zero, the output resistance is R1 × R2 / (R1 + R2). That is 500 Ω in the equal-resistor example. It is distinct from the loaded input resistance, 1,500 Ω. The equivalent predicts the same loaded output using Vth × RL / (Rth + RL); it does not require another input.
What is outside this model?
This is a forward-only nominal resistive DC calculation with an ideal source. It does not choose resistors, model tolerances, temperature, AC reactance, source-current limits or component ratings. A device such as an LED, ADC input or active circuit is not automatically a fixed resistor. Calculated dissipation is not a safe rating, device-suitability decision or supply recommendation. No physical circuit was built or measured.
A zero source is a valid mathematical case: all voltages, currents and powers are zero, while the resistance-defined gains remain meaningful. Zero resistance is a different topology and is rejected. Numeric bounds are computation limits, not recommended operating conditions.
Units, exact inputs and sharing
Choose mV, V or kV for the source and Ω, kΩ or MΩ for each resistor. For example, 1 kΩ, 1,000 Ω and 0.001 MΩ describe the same resistance. Select units separately from the plain decimal; commas, exponents and embedded unit text are not accepted. Unit-only changes preserve the exact original entry until its displayed digits are edited. Exact rational arithmetic precedes all rounded output. Very small positive values use a readable prefix or scientific notation rather than an exact zero.
Copy and print work locally for a complete current result. Public sharing requires a separate unchecked consent control and includes only active numeric inputs and unit preferences. Anyone with the link can recompute the circuit. Invalid, incomplete or unsupported-version links restore no partial circuit. No input is automatically saved or sent on Calculate.
Method sources and review
Analog Devices’ voltage-divider lab, approved revision March 4, 2021, establishes the ground reference and distinguishes series voltage division from parallel current division. Gerald Recktenwald’s 2012 Voltage Dividers and Potentiometers, hosted by SparkFun, develops the loaded and unloaded analysis in sections 2.1–2.3. These electrical relationships support the nominal model; later power-supply applications are not adopted here.
Method reviewed November 8, 2026 using independent nodal, equivalent-resistance and Thevenin checks. The earlier TI PDF retrieval was incomplete and is not treated as a fully reviewed manual. Article examples are not substituted for independently checked arithmetic. This tool is educational computation, with no invented engineering credentials or hardware certification.